Beacon 800
Features
- Low cost versatile solution!
- Capable of up to 8 separate channels
- Digital display of all 8 channels simultaneously
- Compact, weatherproof, NEMA 4X enclosure
- 115 VAC or 24 VDC operation
- Long life sensors (2+ years typical)
- Accepts any 4-20 mA transmitter
- Audible alarm with reset button
- Two programmable alarm levels per channel
- Common alarm and fail relays
- Relay rating 10 amps, form C
Industry Applications
- Petrochemical plants
- Refineries
- Water & wastewater treatment pants
- Pulp & paper mills
- Gas, telephone, & electric utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
- HVAC
Gas detection should not be complicated. The Beacon™ 800 is gas
detection simplified.
The Beacon™ 800 is a simplified, versatile, low cost fixed system
controller for one to eight points of gas detection. It is microprocessor
controlled and is capable of accepting up to 8 separate 4-20 mA sensor
transmitters which can be either 2 or 3 wire. The Beacon™ 800 can
be powered by either 24 VDC or 115 VAC. It is simple to operate and comes
complete with a wall mount installation kit.
The 2 large digital displays have backlighting and easily identify both
the gas type and the gas concentration for all 8 channels simultaneously.
The Beacon™ 800 is also housed in a NEMA 4X rated case for a weather
tight seal. This case design complies with the new lock out / tag out
standard and can be fully secured. An external reset switch allows alarms
to be silenced from outside the controller housing. The bottom mounted
wiring hubs allow for easy wiring.
With 10 amp rated relays, the Beacon™ 800 can be wired directly
to a variety of devices like alarm horns, buzzers, or lights. This eliminates
the need for costly external relays from the controller to devices.
RKI offers the industry’s widest selection of standard and toxic
gas detection sensors, which can be utilized with the Beacon™ 800,
providing gas monitoring protection for almost any application.
Physical |
|
Dimensions |
Height: 12.5” 318 mm Width 11.0” 279 mm Depth 6.4” 163 mm |
Enclosure |
Wall mounting grey polycarbonate with hinged cover. |
Conduit Connection |
3/4” NPT conduit hubs, 4 provided for sensors, power and relay wiring. |
Wiring Termination |
Screw type terminal block 14 gauge max. |
Environmental |
|
Operating Temp |
14°F to 122°F (-10°C to 50°C) |
Storage Temp |
-4°F to 158°F (-20°C to 70°C) |
Relative Humidity |
0 - 100% RH |
Enclosure Rating |
NEMA-4X enclosure, waterproof, chemical, and weather resistant. |
Inputs |
|
4-20 mA Sensors |
Accepts any 4-20 mA transmitter (24VDC,
2 or 3 wire). A wide variety of RKI/Riken sensors are available
with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet. |
Sampling Methods |
Diffusion and sample draw heads available. |
Outputs |
|
Relays |
2 relays per channel 10 amp rating,
SPDT isolated contacts. 1 set of common relays: 2 for gas alarm levels 1 for malfunction Relays fully programmable for: increasing or decreasing alarms latching or self reset normally energized or normally de-energized time delay for alarm on and alarm off. |
24 VDC |
24 VDC output provided to operate sample drawing adapters. |
Display |
2 alphanumeric displays with backlighting. 16 characters per line; 4 lines each. All 8 channels continuously displayed. |
Audible |
Built-in audible alarm, 94 dB, mounted
on enclosure. Coded Output: pulsing = gas alarm steady = Fail |
Visual |
4 visual LED alarms on front cover for alarm indications, pilot, and malfunction. |
Optional Expansion Cards |
Individual 4-20 mA (or 1 - 5 VDC) outputs Heavy duty relay card (4 each @ 30 amps) |
Power |
115 VAC or 12 VDC standard Optional: 230 VAC Battery backup option available |
Warranty |
One year materials and workmanship. |
Partial List Of Detectable Gases
Many other gases or ranges available. Contact RKI for gases or ranges not listed
Ammonia (NH3) |
0 - 75.0 ppm |
| Arsine (AsH3 ) | 0 - 0.20 ppm |
| Boron Trichloride (BCl3) | 0 - 15.0 ppm |
| Carbon Dioxide (CO2) | 0 - 1.0 % |
| Carbon Monoxide (CO) | 0 - 300 ppm |
| Chlorine (Cl2) | 0 - 3.0 ppm |
| Chlorine Dioxide (ClO2) | 0 - 1.00 ppm |
| Chlorine Trifluoride (ClF3) | 0 - 1.00 ppm |
| Combustibles | 0 -100% LEL |
| Diborane (B2H6) | 0 - 30.0 ppm |
| Fluorine (F2) | 0 - 6.0 ppm |
| Hydrogen (H2) | 0 - 2000 ppm |
| Hydrogen Chloride (HCl) | 0 - 15.0 ppm |
| Hydrogen Fluoride (HF) | 0 - 9.0 ppm |
| Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
| Nitric Oxide (NO) | 0 -100.0 ppm |
| Nitrogen Dioxide (NO2) | 0 - 15.0 ppm |
| Nitrogen Trifluoride (NF3) | 0 - 30.0 ppm |
| Oxygen (O2) | 0 - 25.0 % |
| Ozone (O3) | 0 - 1.0 ppm |
| Phosphine (PH3) | 0 - 1.0 ppm |
| Silane (SiH4) | 0 - 15.0 ppm |
| Sulfur Dioxide (SO2) | 0 - 30.0 ppm |
| TEOS (Si(OC2H5)4) | 0 -15/30 ppm |