SM 2000
Features
Stand
alone system, no PC needed for operation
- Calibrate, bump test, charge, and archive data
- Software manages records by serial #, user ID, or station ID
- Each station is equipped with configuration control and status indicators
- User adjustable test times and tolerances
- Automatic quick charge of instrument in 90 minutes or less
- Alkaline recognition – will not attempt to charge alkaline batteries (SM-2003U)
- Exhaust line connection for test gas venting
- Records are stored as a tab delineated text file (.txt format can be imported into a spreadsheet)
- Software is Windows 2000, and XP compatible
- Operates on any Pentium II or higher PC
- USB port for downloading data to a USB flash drive
- USB flash drive included
Models SM-2001U and SM-2003U
The SM-2000 single module calibration station for the GX-2001
and GX-2003 portable gas monitors is a stand alone station that can calibrate,
bump test, charge, and archive data without the need of a computer to operate.
The module has 4 operating modes, which include bump test only, % volume
methane bump/calibration (for the GX-2003), calibration only, and bump
with automatic calibration (if the bump test fails). The SM-2000 modules
are capable of storing up to 200 bump test or calibration records. To download
the data each module includes a 64 MB USB flash drive. Also included is
a software package to import the data from the USB drive and manage records
by serial #, user ID, or station ID. Each module has user adjustable test
times and tolerances to meet specific testing requirements. The charger
within the module quick charges battery packs within 90 minutes and will
recognize alkaline batteries. The Calibration Station power requirements
are 115/230 VAC, 50/60Hz.
| 81-SM2001U | GX-2001 Calibration station, includes power cord, USB flash drive, and software |
| 81-SM2003U | GX-2003 Calibration station, includes power cord, USB flash drive, and software |
| 81-SM2001UC | GX-2001 Calibration station, includes power cord, USB flash drive, and software (evaluated to Canadian electrical code safety standard) |
| 81-SM2003UC | GX-2003 Calibration station, includes power cord, USB flash drive, and software (evaluated to Canadian electrical code safety standard) |
| 81-0154RK-02 | LEL CH4/02/CO/H2S, 58L |
| 81-0155RK-02 | LEL Hexane/02/CO/H2S, 58L |
| 81-0090RK-03 | LEL CH4/02/CO, 103L |
| 81-0089RK-03 | LEL Hexane/02/CO, 103L |
| 81-0013RK-05 | 50% Vol. CH4, 58L |
| 81-0151RK-02 | H2S/N2, 58L |
| 81-0078RK-03 | 100% N2, 103L |
| 81-1054RK | Demand Flow Regulator |
| 06-1248RK-03 | Calibration Tubing, Polyurethane (3/16” x 5/16” x 3) |